江苏春晨电缆有限公司生产JFEYH10KV高压电机引接线,电表箱安装和进户线架设规范图解
Standard diagram for installation of electric meter box and setting up of household line
电表箱安装
Electric meter box installation
1. 电表箱宜选用非金属外壳表箱,如采用金属外壳表箱,应确保表箱外壳可靠接地。
1. the meter box should choose non-metal case. If the metal case is used, it should ensure that the casing of the meter box is reliably grounded.
电表箱安装和进户线架设规范图解
Standard diagram for installation of electric meter box and setting up of household line
2. 单表位表箱应安装于对应用户住宅处。集装表箱安装地点的选择,应确保电表箱后进户线至各用户室内第一支持物或配电装置的最大距离不大于45米。
2. the single meter box should be installed in the corresponding user residence. The choice of installation location of the containerized meter box should ensure that the maximum distance between the back of the meter box and the first support or distribution device of each user room is not greater than 45 meters.
3. 表箱安装高度: 表箱下沿离地高度≥140cm。
3. installation height of watch box: the height of the lower edge of the watch box is more than 140cm.
电表箱安装和进户线架设规范图解
Standard diagram for installation of electric meter box and setting up of household line
4. 表箱安装位置应便于现场抄表、巡视、运维等。不得安装于杆上、用户室内和独立围墙内及危险场所;表箱安装位置应满足防火要求,不应直接安装于木板墙面,安装地点周边应无可燃物;当电能表箱安装于户外墙上时,宜选择在庇荫处,正面留有足够的打开空间,尽量避开屋顶雨水集中排水口和阳光直射处;用于固定表箱的支撑物(墙面等) 应有足够强度;单个墙面安装集中表箱数量不宜超过 2 面。
4. the installation position of the meter box should be convenient for on-site meter reading, inspection, operation and maintenance. It should not be installed on the bar, indoor and independent walls and dangerous places. The location of the table box should meet the fire protection requirements. It should not be installed directly on the board wall, and there should be no combustible in the surrounding area. When the electric energy meter box is installed in the outdoor wall, it should be selected in the shelter and there is enough open space on the front surface. Try to avoid it as far as possible. Open the roof rainwater and the direct sunlight; the support (wall, etc.) for the fixed table box should have enough strength; the number of centralized table boxes installed on a single wall surface should not exceed 2.JFEYH10KV高压电机引接线
5. 表箱安装后,箱体应垂直、牢固,进出线遗留孔洞应实施封堵。
5. after installation of the meter box, the box should be vertical and firm, and the remaining holes in the access line should be blocked.
6. 接户线应三相平衡搭接,对三表位及以上的单相电表箱应采用三相供电,以平均分配负荷;集中电表箱不应超过9表,超过9表应另设电表箱。
The 6. connection line should be balanced by three-phase balance, and three phase and above single-phase meter boxes should be supplied with three phase power supply, with an average distribution of load; the centralized meter box should not exceed 9 meters, and more than 9 meters should be set up by another electric meter box.
进户线架设JFEYH10KV高压电机引接线
Erection of household line
1. 进户线可采用沿绝缘子架空布线、直敷布线、套管布线、线槽布线等敷设方式,并与广播电视、电话等弱电线路分开进线。架空、直敷导线选用 BVV-2×6 铜芯护套线,套管、线槽敷设导线选用 BVV-2×10 铜芯护套线。
The 1. entry line can be laid along the insulator overhead wiring, the direct compress wiring, the casing wiring, the wire grooves wiring and so on, and is separated into the line with the broadcast TV, the telephone and so on. A BVV-2 * 6 copper core sheath wire is selected for overhead and straight conductor conductors, and BVV-2 * 10 copper core sheath wire is used for laying bushing and groove.